C-3101М.1.NP.S.s400.C.00 – the conductometer with raised reliability, primary transducer measuring ranges (0...1); (0...10);
(0...100); (0..1000) μS/cm, Housing material of the electronic unit of the PT – SS321, sensor – submersible (submersible part
is 400mm), contact sensor, without Ex Additional Information:
Operating measuring range 0..200 μS/cm. The output signal 4 ... 20 mA; Reference temperature of termocompensation
25 °С; Material of sensor is SS904, temperature of liquid is 55ºС , pressure of liquid is 0,8MPa. Lenght of cable between MI
and PT – 300m. Lenght of cable between sensor and electronic unit of PT – 15m.
Notes:
When ordering the analyzer with the separated electronic unit and the sensor of the primary converter, the length of the
cable between them, must be lower than 20 m, it is additionally indicated.
When ordering, in addition to the order code, please ,write measuring range, reference temperature for termoconpensation,
operating temperature of liquid, operating pressure of liquid, analog output signal parameters, the color of the MI indicator, the
presence of a signaling relay.
When ordering the analyzer with index K (concentration meter), the normalized dependence of the SEC on the
concentration of the solution must be discussed and coordinated between the customer and the manufacturer.